1-7-5 T2202EA
9. Focus Adjustment
Purpose: Set the optimum Focus.
Symptom of Misadjustment: If Focus Adjustment is
incorrect, blurred images are shown on the display.
Note: Focus VR --- FBT (Sub CBA),
FBT = Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a degaussing coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain a
clear picture.
10. H. Position Adjustment
Purpose: To obtain correct horizontal position of
screen image.
Symptom of Misadjustment: H. position may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [8] button on the remote control unit and
select H-P mode.
2. Input monoscope pattern.
3. Press [CH. o / p] buttons on the remote control
unit so that the left and right side of the
monoscope pattern are equal to each other.
11. V. Shift Adjustment
Purpose: To obtain correct vertical position of screen
image.
Symptom of Misadjustment: If V. position is
incorrect, vertical position of image on the screen may
not be properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-P mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH. o / p] buttons on the remote control
unit so that the top and bottom of the monoscope
pattern are equal to each other.
12. V. Size Adjustment
Purpose: To obtain correct vertical height of screen
image.
Symptom of Misadjustment: If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
1. Enter the Service mode. (See page 1-7-1.)
Press [9] button on the remote control unit and
select V-S mode. (Press [9] button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press [CH. o / p] buttons on the remote control
unit so that the monoscope pattern is 90±5% of
display size and the circle is round.
Test Point Adj. Point Mode Input
--- Focus Control --- Monoscope
Tape M. EQ. Spec.
--- Pattern Generator See below
Test Point Adj. Point Mode Input
---
[CH. o / p]
buttons
--- Monoscope
Tape M. EQ. Spec.
--- Pattern Generator ---
Test Point Adj. Point Mode Input
---
[CH. o / p]
buttons
--- Monoscope
Tape M. EQ. Spec.
--- Pattern Generator ---
Test Point Adj. Point Mode Input
---
[CH. o / p]
buttons
--- Monoscope
Tape M. EQ. Spec.
--- Pattern Generator 90±5%
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 81 82

Comentarios a estos manuales

Sin comentarios

Gme GR100 manuals

Owner’s manuals and user’s guides for Multimedia Gme GR100.
We providing 1 pdf manuals Gme GR100 for download free by document types: User Manual






More products and manuals for Multimedia Gme

Models Document Type
GR9240W User Manual   GME GR9240W User Manual, 20 pages
GR968 User Manual   GME GR968 User Manual, 12 pages
SPK002W User Manual   GME SPK002W User Manual, 8 pages
SPK008B User Manual   GME SPK008B User Manual, 4 pages